Tiger - Vac

Tiger - Vac
Fuel and solvents recovery vacuum cleaner systems: 
ATEX Category 2 Explosion proof vacuum cleaner systems for ATEX Zone 1 (Gas) and 
ATEX Zone 21 (Dust) (where indicated)
 
Tiger-Vac’s Fuel and solvent recovery vacuum cleaner systems are specifically designed for the recovery of highly flammable, toxic liquids. These vacuum cleaner systems are equipped with a series of features and a variety of options.
These vacuums cleaner systems are ideal for the de-fueling and de-puddling of fuel tanks and wings on military or civilian airplanes, as well as for recovering fuel spills. All parts of the vacuum cleaner system have electrical continuity and bonding techniques to ensure static dissipation. These vacuum cleaner systems are legally certified for use in ATEX Zone 1 (Gas) and ATEX Zone 21 (Dust) and are available in electrically or pneumatically (air) operated versions.
Please consult the brochures or contact us for more information and specifications on Tiger-Vac’s Fuel, Solvent and Acid recovery vacuum cleaner systems.
 
 
 
 
 
About the F-35:
 
The F-35 Lightning II is a 5th generation fighter, combining advanced stealth with fighter speed and agility, fully fused sensor information, network-enabled operations and advanced sustainment. As new threats to freedom emerge, it is more important than ever for U.S. and allied fighter fleets to have the F-35—the world’s only 5th Generation, international, multirole aircraft, capable of countering current and future threats.
Find out more about the F-35 by visiting http://www.f35.com.
 
 
 
Sort By:
Show:
Display: List Grid
  • SS-15 to 55 (TC) TE SERIES
    Fuel and Solvent Recovery Pneumatic (Air) Model   Certifications   GUARANTEED to be capable of safely recovering combustible/flammable liquids. Capable of safely recovering combustible dusts when equipped with optional filters for dry recovery.     II 2 G/D c IIC T6 (85oC) LCIE 03 ATEX 6310       All stainless steel SAE 304 construction (except cart) with red and yellow bands..
  • SS-25 AC TE (HY-C)
    Fuel and Solvent Recovery Pneumatic (Air) Model   Certifications     GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.   II 2 G/D c IIC T6 (85oC) LCIE 03 ATEX 6310       Stainless steel Activated Carbon Drum  with red and yellow bands and powder coated Hydraulic Cart.  Less than 10 Ohms of resistivity.  This uni..
  • SS-25 HRS TE (HY-C) Hydrazine Recovery
    Hydrazine Recovery Pneumatic Air Model   Certifications   GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.   II 2 G/D c IIC T6 (85oC) LCIE 03 ATEX 6310   Stainless steel Drum with red and yellow bands and powder coated Hydraulic Cart. Less than 10 Ohms of resistivity. This unit is equipped with a Coalescing Filter Element (CFE) for moisture removal. An optional true HEP..
  • SS-55 HRS TE (HY-C)
    Hydrazine Recovery Pneumatic (Air) Model     Certifications       GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.    II 2 G/D c IIC T6 (85oC) LCIE 03 ATEX 6310     Stainless steel Drum with red and yellow bands and powder coated Hydraulic Cart. Less than 10 Ohms of resistivity. This unit is equipped with a Coalescing Fil..
  • SS-55 (DM/DMB) TE SERIES
    Fuel and Solvent Recovery Pneumatic (Air) Model   Certifications   GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids. II 2 G/D c IIC T6 (85oC) LCIE 03 ATEX 6310     All stainless steel SAE 304 construction (except cart) with red and yellow bands.  Less than 10 Ohms of resistivity.  This unit is available with an optional Activated Carbon Cartridge for the adsorp..
  • AC-25 (4W) EX
    Pharma* - Activated Carbon Drum System Pneumatic (Air) Model   Certifications   GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.   All stainless steel SAE 304 construction.  Less than 10 Ohms of resistivity.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  Designed as a secondary fume and vapor recovery unit.  This unit has a capacity..
  • EXP1-15 to 55 (TC) TE SERIES
    Fuel and Solvent Recovery Electric Model   Certifications   GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.   EXP1 Series IECEX Certified Ex d IIA T4 Gb Ex t IIIC T 120°C Db IP65 IECEx LCI 10.0039 Vacuum Cleaner certified for providing an Equipment Protection Level of EPL Db and EPL Gb See Certificate    0081  II 2 G/D Ex d IIA T4 Gb ..
  • EXP1-55 (DMB) TE
    Fuel & Solvent Recovery   Certifications   GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids. EXP1 Series IECEX Certified Ex d IIA T4 Gb Ex t IIIC T 120°C Db IP65 IECEx LCI 10.0039 Vacuum Cleaner certified for providing an Equipment Protection Level of EPL Db and EPL Gb See Certificate  0081  II 2 G/D Ex d IIA T4 Gb Ex t IIIC T120oC Db IP65 LCIE 03 ATEX 6..
  • CD-25 EX MRAC (HY-C)
    Fuel & Solvent Recovery   Certifications   GUARANTEED to be capable of safely recovering combustible/flammable liquids. Capable of safely recovering combustible dusts when equipped with optional filters for dry recovery.   CD EX series IECEx Certified Ex d IIB T4 Gb Ex t IIIC T135oC Db IP65 IECEx LCI 10.0040 Vacuum Cleaner certified for providing an Equipment Protection Level of EPL Db and EPL Gb See Certificate ..